Processing Steps |
- Parameter or Variable: Dissolved Inorganic Carbon; Abbreviation: DIC; Unit: umol/kg; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Manipulation condition; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing; Analyzing instrument: Infra-red detector; Detailed sampling and analyzing information: Apollo SciTech's DIC AS-C3, Bogart, GA, USA, small volumes less than 1 mL, precission plus minus 2 umol/kg; Standardization description: Used CRM to ensure accuracy of instrument during sampling; Standardization frequency: every 3 hours during anlaysis; CRM manufacturer: Andrew Dickson's lab at Scripps Institute of Oceanography; Preservation method: None ran within 5 minutes of collecting sample; Preservative volume: None; Preservative correction: no correction.; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Total alkalinity; Abbreviation: TA; Unit: umol/kg; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Manipulation condition; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing; Analyzing instrument: Alkalinity titrator, pH electrode ws Model 8104BNUWP Ross ultra glass combination pH electrod with rugged bulb. Electrode was calibrated using a trise base buffer at pH 8.094 from Andrew Dickson Batch 7, Bottle 102; Cell type (open or closed): Open; CRM manufacturer: Andrew Dickson's lab at Scripps Institute of Oceanography; CRM batch number: CRM 112 and CRM 98; Preservation method: None; Preservative volume: None; Preservative correction: no correction.; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: pH; Abbreviation: pH; pH scale: Total; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Manipulation condition; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing; Analyzing instrument: Varian Cary 100 Spectrometer; Temperature of pH measurement: 20 C; Detailed sampling and analyzing information: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing was used to fill 10 mm cells. pH measurements were taken at 20C and recorded at 20C. Dye batch number was lot number 1080-0253; Temperature of standardization: 20; Temperature correction method: none; At what temperature was pH reported: 20; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Date of water collection; Abbreviation: Collection Date; Detailed sampling and analyzing information: This is the date that the water sample was collected from the coordinates above, Water was filtered to 0.22 um and stored in the cold (4C) until utalized for experiments; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Date of experiment; Abbreviation: Date; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Species; Abbreviation: Species; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Light Intensity; Abbreviation: Light; Unit: umoles m2s-1; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Manipulated condition; Measured or calculated: Measured; Analyzing instrument: Li-Cor, Inc. Model LI-185B Quantum photometer; Replicate information: triplicate measurements along the light source, light was on for 14 hours per day; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Salinity; Abbreviation: S; Controlled vocabulary name: Salinity; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Manipulation condition; Measured or calculated: Measured; Sampling instrument: Glass pipette; Analyzing instrument: Refractometer Atago; Detailed sampling and analyzing information: refractometer was zerod with Milli-Q water at 18 ohms. Once zeroed refractometer was cleaned and a drop of seawater was put on it and measurments were taken.; Replicate information: triplicate measurements; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: dissolved silicate; Abbreviation: Si; Unit: umol/Kg; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Manipulation condition; Measured or calculated: measured; Analyzing instrument: Quattro, Test range0-20umol/L, 10 mm flowcell with LED photometer at 820 nm, 60 samples/hr, standard deviation is 0.05 umol/L, detetion limit is 0.01 umol/L; Detailed sampling and analyzing information: Samples were taken in 250 ml amber polypropylene bottles and ran immediately after collection; Method reference: Method NO Q-066-05 Rev. 3 for QuAAtro Applications developed by the Royal Netherlands Institute for Sea Research; Researcher name: Shannon Meseck; Researcher institution: National Marine Fisheries Service.
- Parameter or Variable: Dissolved Phosphate; Abbreviation: P; Unit: umol/Kg; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Manipulation condition; Measured or calculated: Measured; Analyzing instrument: Quattro, Test range 0-4 umol/L, 10 mm flowcell with LED photometer at 880 nm, 60 samples/hr, standard deviation is 0.01 umol/L, detetion limit is 0.004umol/L; Detailed sampling and analyzing information: Samples were taken in 250 ml amber polypropylene bottles and ran immediately after collection; Method reference: Method NO Q-064-05 Rev. 3 for QuAAtro Applications developed by the Royal Netherlands Institute for Sea Research; Researcher name: Shannon Meseck; Researcher institution: National Marine Fisheries Service.
- Parameter or Variable: Dissolved nitrate+nitrite; Abbreviation: N; Unit: umol/Kg; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Manipulated condition; Measured or calculated: Measured; Analyzing instrument: Quattro, Test range 0-250 umol/L, 10 mm flowcell with LED photometer at 520nm, 90 samples/hr, standard deviation is 0.03 umol/L, detetion limit is 0.02 umol/L; Detailed sampling and analyzing information: Samples were taken in 250 ml amber polypropylene bottles and ran immediately after collection; Method reference: Method NO Q-068-05 Rev. 4 for QuAAtro Applications developed by the Royal Netherlands Institute for Sea Research; Researcher name: Shannon Meseck; Researcher institution: National Marine Fisheries Service.
- Parameter or Variable: Alkalinity Corrected; Abbreviation: AC; Unit: umol/ kg; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Manipulation condition; Measured or calculated: measured; Analyzing instrument: Alkalinity titrator; Detailed sampling and analyzing information: Known CRM were used with our alkalinity titrator. The differences between our measured alkalinity and the reported alkalinity is recorded in this column.; Replicate information: Triplicates; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: DIC Corrected; Abbreviation: DIC Cor; Unit: umol/ kg; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Manipulation condition; Measured or calculated: measured; Analyzing instrument: Infra-red detector; Detailed sampling and analyzing information: Apollo SciTech's DIC AS-C3, Bogart, GA, USA, small volumes less than 1 mL, precission plus minus 2 umol/kg; Replicate information: Triplicates; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: CRM adjusted alkalinity; Abbreviation: CRM adj alk; Unit: umol/ kg; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Manipulation condition; Measured or calculated: measured; Analyzing instrument: Alkalinity titrator; Detailed sampling and analyzing information: Known CRM were used with our alkalinity titrator. The differences between our measured alkalinity and the reported alkalinity is corrected in this column by how much the CRM was off.; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: CRM adjusted Dissolved Inorganic Carbon; Abbreviation: CRM adj DIC; Unit: umol/ kg; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Manipulation condition; Measured or calculated: measured; Analyzing instrument: Infra-red detector; Detailed sampling and analyzing information: Apollo SciTech's DIC AS-C3, Bogart, GA, USA, small volumes less than 1 mL, precission plus minus 2 umol/kg; Quality flag convention: This is the correct data based on CRM values that we obtained with the Apollo SciTech instrument. We corrected our measurements accordingly.; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Alkalnity pH calculated pCO2 from CO2SYS; Abbreviation: Alk-pH pCO2; Unit: ppm; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Manipulation condition; Measured or calculated: Calculated; Detailed sampling and analyzing information: CO2SYS; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Alkalnity DIC calculated pCO2 from CO2SYS; Abbreviation: Alk-DIC pCO2; Unit: ppm; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Manipulation condition; Measured or calculated: Calculated; Detailed sampling and analyzing information: CO2SYS; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: DIC pH calculated pCO2 from CO2SYS; Abbreviation: DIC-pH pCO2; Unit: ppm; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Manipulation condition; Measured or calculated: Calculated; Detailed sampling and analyzing information: CO2SYS; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: division rate; Abbreviation: u; Unit: d-1; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: measured; Detailed sampling and analyzing information: growth rate are calculted by the number of cells difference from the intial experiment to the end of the experiment; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: particulate nitrogen; Abbreviation: Part N; Unit: umol/ l; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 250 ml amber bottles.; Analyzing instrument: Costech ECS 4010 elemental analyzer; Duration: experiment studied; Detailed sampling and analyzing information: Samples were taken in 250 ml amber polypropylene bottles and filtered on 500C combusted GF/F filters. Filters where then dried, rolled and ran on the elemental analyzer.; Replicate information: Doublicate samples were taken from each culture; Biological subject: Phytoplankton; Researcher name: Shannon Meseck; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: particulate carbon; Abbreviation: Part C; Unit: umol/ l; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 250 ml amber bottles.; Analyzing instrument: Costech ECS 4010 elemental analyzer; Detailed sampling and analyzing information: Samples were taken in 250 ml amber polypropylene bottles and filtered on 500C combusted GF/F filters. Filters where then dried, rolled and ran on the elemental analyzer.; Replicate information: Doublicate samples were taken from each culture; Biological subject: Phytoplankton; Researcher name: Shannon Meseck; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: particulate phosphate; Abbreviation: Part P; Unit: umol/ l; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 250 ml amber bottles.; Analyzing instrument: Costech ECS 4010 elemental analyzer; Detailed sampling and analyzing information: Samples were taken in 250 ml amber polypropylene bottles and filtered on 500C combusted GF/F filters. Filters where then dried, rolled and ran on the elemental analyzer.; Method reference: Fu, F., et al. "The biological and biogeochemical consequences of phosphate scavenging onto phytoplankton cell surfaces." Limnology and oceanography 50.5 (2005): 1459.; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: biogenic silica; Abbreviation: Part Si; Unit: umol/ l; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 250 ml amber bottles.; Detailed sampling and analyzing information: Samples were taken in 250 ml amber polypropylene bottles and filtered on; Method reference: Nelson, David M., Treguer, Paul, Brzezinski, Mark A., Leynaert, Aude, Queguiner, Bernard. 1995. Production and dissolution of biogenic silica in the ocean: Revised global estimates, comparison with regional data and relationship to biogenic sedimentation Global Biogeochem. Cycles 9:359-372.; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Final cell counts; Abbreviation: Final cells; Unit: cells/ ml; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 250 ml amber bottles.; Analyzing instrument: Fascan flow cytometer; Detailed sampling and analyzing information: 1 ml samples were taken and ran on a flow cytometer to get final cell counts using FL-3 fluorescence and side scatter; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: hydrocarbons; Abbreviation: HC; Unit: % of total lipids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Iatroscan Model number MK-6s; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Kenneth Hammel; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: steryl esters/wax esters; Abbreviation: SE/WE; Unit: % of total lipids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Iatroscan Model number MK-6s; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Kenneth Hammel; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: ethyl esters; Abbreviation: EE; Unit: % of total lipids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Iatroscan Model number MK-6s; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Kenneth Hammel; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: methyl esters; Abbreviation: ME; Unit: % of total lipids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Iatroscan Model number MK-6s; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Kenneth Hammel; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: ethyl ketones; Abbreviation: EK; Unit: % of total lipids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Iatroscan Model number MK-6s; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Kenneth Hammel; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: methyl ketones; Abbreviation: MK; Unit: % of total lipids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Iatroscan Model number MK-6s; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Kenneth Hammel; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: gylcerol ethers; Abbreviation: GE; Unit: % of total lipids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Iatroscan Model number MK-6s; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Kenneth Hammel; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Triacylglycerols; Abbreviation: Triacylglycerols; Unit: % of total lipids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Iatroscan Model number MK-6s; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Kenneth Hammel; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: free fatty acids; Abbreviation: FFA; Unit: % of total lipids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Iatroscan Model number MK-6s; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Kenneth Hammel; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Alcohols; Abbreviation: Alcohols; Unit: % of total lipids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Iatroscan Model number MK-6s; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Kenneth Hammel; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Sterols; Abbreviation: Sterols; Unit: % of total lipids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Iatroscan Model number MK-6s; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Kenneth Hammel; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: diacylglycerols; Abbreviation: diacylglycerols; Unit: % of total lipids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Iatroscan Model number MK-6s; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Kenneth Hammel; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: acetone mobile polar lipids; Abbreviation: AMPL; Unit: % of total lipids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Iatroscan Model number MK-6s; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Kenneth Hammel; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Phospholipids; Abbreviation: Phospholipids; Unit: % of total lipids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Iatroscan Model number MK-6s; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Kenneth Hammel; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 14:0; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: trimethyltrideconoic acid; Abbreviation: TMTD; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 14:1; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: i15:0; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: ai15:0; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 15:0; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 15:1; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: i16:0; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: ai16:0?; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: pristanic?; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 16:0; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 16:1w11?; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 16:1w9?; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 16:1w7; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 16:1w5; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: i17:0; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: ai17:0; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 16:2w4; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: phytanic?; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 17:0; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 16:3w4?; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 17:1; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 16:3w3?; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 16:4w3?; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 16:4w1; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 18:0; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 18:1w11?; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 18:1w9; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 18:1w7; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 18:1w6?; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 18:1w5?; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 18:2a; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 18:2b; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 18:2w6; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 18:2w4; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 18:3w6; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 19:0; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 18:3w4; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 18:3w3; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 18:4w3; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 18:4w1?; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 20:0; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 18:5w3; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 20:1w11?; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 20:1w9; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 20:1w7?; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 20:2a?; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 20:2b?; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 20:2w6; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 20:3w6; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 21:0; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 20:4w6; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 20:3w3; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 20:4w3; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 20:5w3; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 22:0; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 22:1w11(13); Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 22:1w9; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 22:1w7; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 22:2NIMDa?; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 22:2NIMDb?; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 21:5w3?; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 23:0; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 22:4w6?; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 22:5w6; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 22:4w3?; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 22:5w3; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 24:0; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 22:6w3; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration.
- Parameter or Variable: Fatty acids; Abbreviation: 24:1; Unit: % of total fatty acids; Observation type: Laboratory experiment; In-situ / Manipulation / Response variable: Response variable; Measured or calculated: Measured; Sampling instrument: 0.25 in Inner Diamter X 0.375 in Outer Diamter Silicone Tubing into 1 L amber bottles.; Analyzing instrument: Gas Chromotagraph; Duration: experiment studied; Detailed sampling and analyzing information: All samples were collected on combusted (500 C) GF/C filters (1 l minimum filtered) and stored in glass test tubes that were lipid cleaned.; Method reference: Parrish, CC (1999. Determination of total lipid, lipid classes and fatty acids in equatic samples. Lipids in freshwater ecosytems. MA arts, BC wainman New York, Springer Verlag:4-12; Biological subject: Phytoplankton; Researcher name: Andrew King; Researcher institution: Northeast Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration .
|