Skip to main content
Dataset Overview | National Centers for Environmental Information (NCEI)

Organic chemical contaminants measured by PED (polyethylene device) passive water samplers deployed at Cocos Island, Guam from 2017-09-18 to 2017-10-30 (NCEI Accession 0184259)

browse graphicPreview graphic
The Cocos Island, Guam PEDs (polyethylene device) passive water sampler data set contains results of the analysis from Project 31181 funded by NOAA’s Coral Reef Conservation Program. The project involved NOAA National Center for Coastal Ocean Science, Guam Environmental Protection Agency and the United States Environmental Protection Agency. The data resulted from the deployment of an array of PEDs passive water samplers in the waters around Cocos Island in Cocos Lagoon, Guam. Duplicate PEDs were deployed at 26 sites by NOAA and Guam EPA personnel in September 2017, and then retrieved one month later by Guam EPA personnel. At 22 sites, the PEDs were deployed in the water column along six transects on the northwest shore of Cocos Island; an additional PED was deployed in the water column along the southeast shore. At two sites (9-1 and 9-2), PEDs were embedded in the sand along the shore, with the remaining PED (4-3 #035) embedded in the sand underwater at site 4-3.

The duplicate PEDs from each site were combined and analyzed as one sample, in an effort to increase the sensitivity of the analysis (lower detection limit). The PEDs were analyzed for a series of organic chemical contaminants including polychlorinated biphenyls (PCBs), organochlorine pesticides and petroleum hydrocarbons (PAHs), all of which are contaminants of concern in the area. The polyethylene sheets comprising the PEDs at each site was analyzed, and the results are reported as nanograms of contaminant per each analysis, or ng/ea.
  • Cite as: Pait, Tony; Hartwell, Ian; Mason, Andrew; Apeti, Dennis; Cruz, Jesse; Mills, Marc (2019). Organic chemical contaminants measured by PED (polyethylene device) passive water samplers deployed at Cocos Island, Guam from 2017-09-18 to 2017-10-30 (NCEI Accession 0184259). [indicate subset used]. NOAA National Centers for Environmental Information. Dataset. https://doi.org/10.25921/a4ev-8453. Accessed [date].
gov.noaa.nodc:0184259
Download Data
  • HTTPS (download)
    Navigate directly to the URL for data access and direct download.
  • FTP (download)
    These data are available through the File Transfer Protocol (FTP). FTP is no longer supported by most internet browsers. You may copy and paste the FTP link to the data into an FTP client (e.g., FileZilla or WinSCP).
Distribution Formats
  • CSV
Ordering Instructions Contact NCEI for other distribution options and instructions.
Distributor NOAA National Centers for Environmental Information
+1-301-713-3277
NCEI.Info@noaa.gov
Dataset Point of Contact NOAA National Centers for Environmental Information
ncei.info@noaa.gov
Time Period 2017-09-18 to 2017-10-30
Spatial Bounding Box Coordinates
West: 144.643
East: 144.661
South: 13.234
North: 13.2458
Spatial Coverage Map
General Documentation
Associated Resources
Publication Dates
  • publication: 2019-03-08
Data Presentation Form Digital table - digital representation of facts or figures systematically displayed, especially in columns
Dataset Progress Status Complete - production of the data has been completed
Historical archive - data has been stored in an offline storage facility
Data Update Frequency As needed
Supplemental Information
Submission Package ID: T643WC
Purpose These data were collected in support of a project conducted with partners at Guam EPA and the USEPA to assess the presence of chemical contaminants in the waters around Cocos Island, Guam, as a means for contaminant exposure and subsequent uptake in resident biota such as fish.
Use Limitations
  • accessLevel: Public
  • Distribution liability: NOAA and NCEI make no warranty, expressed or implied, regarding these data, nor does the fact of distribution constitute such a warranty. NOAA and NCEI cannot assume liability for any damages caused by any errors or omissions in these data. If appropriate, NCEI can only certify that the data it distributes are an authentic copy of the records that were accepted for inclusion in the NCEI archives.
Dataset Citation
  • Cite as: Pait, Tony; Hartwell, Ian; Mason, Andrew; Apeti, Dennis; Cruz, Jesse; Mills, Marc (2019). Organic chemical contaminants measured by PED (polyethylene device) passive water samplers deployed at Cocos Island, Guam from 2017-09-18 to 2017-10-30 (NCEI Accession 0184259). [indicate subset used]. NOAA National Centers for Environmental Information. Dataset. https://doi.org/10.25921/a4ev-8453. Accessed [date].
Cited Authors
Contributors
Resource Providers
Points of Contact
Publishers
Acknowledgments
  • Related Funding Agency: NOAA Coral Reef Conservation Program
Theme keywords NODC DATA TYPES THESAURUS NODC OBSERVATION TYPES THESAURUS WMO_CategoryCode
  • oceanography
CoRIS Discovery Thesaurus
  • Numeric Data Sets > Chemical Contaminants
CoRIS Theme Thesaurus
  • EARTH SCIENCE > Human Dimensions > Environmental Impacts > Contaminants
  • EARTH SCIENCE > Hydrosphere > Water Quality > Contaminants
  • EARTH SCIENCE > Hydrosphere > Water Quality > Contaminants > Chemical
  • EARTH SCIENCE > Oceans > Ocean Chemistry > Chemistry Monitoring and Assessment
Global Change Master Directory (GCMD) Science Keywords NCCOS Keywords
  • NCCOS Research Data Type > Field Observation
  • NCCOS Research Data Type > Long-term Monitoring
  • NCCOS Research Location > Region > Pacific Ocean
  • NCCOS Research Location > U.S. States and Territories > Guam
  • NCCOS Research Priority > Stressor Impacts and Mitigation
  • NCCOS Research Topic > Biological Effects of Contaminants and Nutrients
Submitter Provided Datatype Keywords
  • 1,2,3,4-Tetrachlorobenzene
  • 1,2,4,5-Tetrachlorobenzene
  • 2,4'-DDD
  • 2,4'-DDE
  • 2,4'-DDT
  • 4,4'-DDD
  • 4,4'-DDE
  • 4,4'-DDT
  • Acenaphthene
  • Acenaphthylene
  • Aldrin
  • Alpha-Chlordane
  • Alpha-HCH
  • Anthracene
  • Benz(a)anthracene
  • Benzo(a)fluoranthene
  • Benzo(a)pyrene
  • Benzo(b)fluoranthene
  • Benzo(e)pyrene
  • Benzo(g,h,i)perylene
  • Benzo(k,j)fluoranthene
  • Benzothiophene
  • Beta-HCH
  • Biphenyl
  • C1-Benzothiophenes
  • C1-Chrysenes
  • C1-Decalins
  • C1-Dibenzothiophenes
  • C1-Fluoranthenes/Pyrenes
  • C1-Naphthalenes
  • C1-Naphthobenzothiophenes
  • C1-Phenanthrenes/Anthracenes
  • C2-Benzothiophenes
  • C2-Chrysenes
  • C2-Dibenzothiophenes
  • C2-Fluoranthenes/Pyrenes
  • C2-Fluorenes
  • C2-Naphthalenes
  • C2-Naphthobenzothiophenes
  • C2-Phenanthrenes/Anthracenes
  • C3-Benzothiophenes
  • C3-Chrysenes
  • C3-Decalins
  • C3-Dibenzothiophenes
  • C3-Fluoranthenes/Pyrenes
  • C3-Fluorenes
  • C3-Naphthalenes
  • C3-Naphthobenzothiophenes
  • C3-Phenanthrenes/Anthracenes
  • C4-Benzothiophenes
  • C4-Chrysenes
  • C4-Decalins
  • C4-Dibenzothiophenes
  • C4-Fluoranthenes/Pyrenes
  • C4-Naphthalenes
  • C4-Naphthobenzothiophenes
  • C4-Phenanthrenes/Anthracenes
  • Carbazole
  • Chrysene/Triphenylene
  • Cis-Nonachlor
  • DDMU
  • Decalins
  • Delta-HCH
  • Dibenzo(a,h)anthracene
  • Dibenzofuran
  • Dibenzothiophene
  • Dieldrin
  • Endosulfan I
  • Endosulfan II
  • Endosulfan Sulfate
  • Endrin
  • Endrin Aldehyde
  • Endrin Ketone
  • Fluoranthene
  • Fluorene
  • Fluorenes
  • Gamma-Chlordane
  • Gamma-HCH
  • Heptachlor
  • Heptachlor-Epoxide
  • Hexachlorobenzene
  • Indeno(1,2,3-c,d)pyrene
  • Mirex datatypes-94: Chlorpyrifos
  • Naphthalene
  • Naphthobenzothiophene
  • Oxychlordane
  • PCB 1
  • PCB 100
  • PCB 101/89/113
  • PCB 102/98
  • PCB 104
  • PCB 105/127
  • PCB 108/107
  • PCB 109
  • PCB 11
  • PCB 110
  • PCB 111/115/87
  • PCB 112
  • PCB 114/122
  • PCB 116/117
  • PCB 118/106
  • PCB 119
  • PCB 12
  • PCB 120/83
  • PCB 121/93/95
  • PCB 123
  • PCB 124
  • PCB 126
  • PCB 128/167
  • PCB 129
  • PCB 13
  • PCB 130
  • PCB 132
  • PCB 134/133
  • PCB 135
  • PCB 136/154
  • PCB 137
  • PCB 138/160/158
  • PCB 14
  • PCB 140
  • PCB 141
  • PCB 142/146/161
  • PCB 143
  • PCB 144
  • PCB 147
  • PCB 148/145
  • PCB 149/139
  • PCB 15
  • PCB 150
  • PCB 151
  • PCB 152
  • PCB 153/168
  • PCB 155
  • PCB 156
  • PCB 157
  • PCB 159
  • PCB 16/32
  • PCB 162
  • PCB 164/163
  • PCB 165/131
  • PCB 166
  • PCB 169
  • PCB 17
  • PCB 170/190
  • PCB 171
  • PCB 173
  • PCB 174
  • PCB 175
  • PCB 176
  • PCB 177
  • PCB 179
  • PCB 18
  • PCB 180/193
  • PCB 181
  • PCB 183
  • PCB 184
  • PCB 185
  • PCB 186/178
  • PCB 187/182
  • PCB 188
  • PCB 189
  • PCB 19
  • PCB 191
  • PCB 192/172
  • PCB 194
  • PCB 195
  • PCB 197
  • PCB 198
  • PCB 199
  • PCB 2
  • PCB 200
  • PCB 201
  • PCB 202
  • PCB 203/196
  • PCB 204
  • PCB 205
  • PCB 206
  • PCB 207
  • PCB 208
  • PCB 209
  • PCB 21/20/33
  • PCB 22
  • PCB 23
  • PCB 24
  • PCB 25
  • PCB 26
  • PCB 27
  • PCB 28/31
  • PCB 29
  • PCB 3
  • PCB 30
  • PCB 34
  • PCB 35
  • PCB 36
  • PCB 37
  • PCB 38
  • PCB 39
  • PCB 4/10
  • PCB 40/57
  • PCB 42
  • PCB 43
  • PCB 44
  • PCB 45
  • PCB 46/69/73
  • PCB 48/75/47
  • PCB 49
  • PCB 50
  • PCB 51
  • PCB 52
  • PCB 53
  • PCB 54
  • PCB 55
  • PCB 56
  • PCB 58
  • PCB 59
  • PCB 6
  • PCB 60
  • PCB 61/74
  • PCB 62
  • PCB 63
  • PCB 65
  • PCB 66/80
  • PCB 67
  • PCB 68/41/64
  • PCB 7/9
  • PCB 71
  • PCB 72
  • PCB 76/70
  • PCB 77
  • PCB 78
  • PCB 79
  • PCB 8/5
  • PCB 81
  • PCB 82
  • PCB 84/90
  • PCB 85
  • PCB 88
  • PCB 91
  • PCB 92
  • PCB 94
  • PCB 96/103
  • PCB 97/125/86
  • PCB 99
  • Pentachloroanisole
  • Pentachlorobenzene
  • Perylene
  • Phenanthrene
  • Pyrene
  • Total Chlordane
  • Total DDT
  • Total HCH
  • Total PAHs
  • Total PCB
  • Trans-Nonachlor
  • cis/trans Decalin
Data Center keywords NODC COLLECTING INSTITUTION NAMES THESAURUS NODC SUBMITTING INSTITUTION NAMES THESAURUS Global Change Master Directory (GCMD) Data Center Keywords
Instrument keywords NODC INSTRUMENT TYPES THESAURUS Global Change Master Directory (GCMD) Instrument Keywords Provider Instruments
  • gas chromatograph/electron capture detection
  • gas chromatograph/mass spectrometer
Place keywords NODC SEA AREA NAMES THESAURUS CoRIS Place Thesaurus
  • COUNTRY/TERRITORY > United States of America > Guam > Cocos Island (13N144E0019)
  • COUNTRY/TERRITORY > United States of America > Guam > Cocos Lagoon (13N144E0057)
  • COUNTRY/TERRITORY > United States of America > Guam > Guam (13N144E0000)
  • OCEAN BASIN > Pacific Ocean > Western Pacific Ocean > Cocos Barrier Reef > Cocos Island (13N144E0019)
  • OCEAN BASIN > Pacific Ocean > Western Pacific Ocean > Guam > Cocos Lagoon (13N144E0057)
  • OCEAN BASIN > Pacific Ocean > Western Pacific Ocean > Guam > Guam (13N144E0000)
Global Change Master Directory (GCMD) Location Keywords
Project keywords NODC PROJECT NAMES THESAURUS CRCP Project
  • 31181
  • Cocos Island Guam Passive Water Sampler Study
Keywords NCEI ACCESSION NUMBER
Use Constraints
  • Cite as: Pait, Tony; Hartwell, Ian; Mason, Andrew; Apeti, Dennis; Cruz, Jesse; Mills, Marc (2019). Organic chemical contaminants measured by PED (polyethylene device) passive water samplers deployed at Cocos Island, Guam from 2017-09-18 to 2017-10-30 (NCEI Accession 0184259). [indicate subset used]. NOAA National Centers for Environmental Information. Dataset. https://doi.org/10.25921/a4ev-8453. Accessed [date].
Access Constraints
  • Use liability: NOAA and NCEI cannot provide any warranty as to the accuracy, reliability, or completeness of furnished data. Users assume responsibility to determine the usability of these data. The user is responsible for the results of any application of this data for other than its intended purpose.
Fees
  • In most cases, electronic downloads of the data are free. However, fees may apply for custom orders, data certifications, copies of analog materials, and data distribution on physical media.
Lineage information for: dataset
Processing Steps
  • 2019-03-08T18:28:20Z - NCEI Accession 0184259 v1.1 was published.
Output Datasets
Lineage information for: dataset
Processing Steps
  • Parameter or Variable: cis/trans Decalin (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C1-Decalins (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C2-Decalins (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C3-Decalins (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C4-Decalins (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: Naphthalene (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C1-Naphthalenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C2-Naphthalenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C3-Naphthalenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C4-Naphthalenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: Benzothiophene (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C1-Benzothiophenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C2-Benzothiophenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C3-Benzothiophenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C4-Benzothiophenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: Biphenyl (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: Acenaphthylene (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: Acenaphthene (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: Dibenzofuran (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: Fluorene (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C1-Fluorenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C2-Fluorenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C3-Fluorenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: Carbazole (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: Anthracene (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: Phenanthrene (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C1-Phenanthrenes/Anthracenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C2-Phenanthrenes/Anthracenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C3-Phenanthrenes/Anthracenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C4-Phenanthrenes/Anthracenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: Dibenzothiophene (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C1-Dibenzothiophenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C2-Dibenzothiophenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C3-Dibenzothiophenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C4-Dibenzothiophenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: Fluoranthene (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: Pyrene (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C1-Fluoranthenes/Pyrenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C2-Fluoranthenes/Pyrenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C3-Fluoranthenes/Pyrenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C4-Fluoranthenes/Pyrenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: Naphthobenzothiophene (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C1-Naphthobenzothiophenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C2-Naphthobenzothiophenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C3-Naphthobenzothiophenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C4-Naphthobenzothiophenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: Benz(a)anthracene (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: Chrysene/Triphenylene (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C1-Chrysenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C2-Chrysenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C3-Chrysenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: C4-Chrysenes (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: Benzo(b)fluoranthene (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: Benzo(k,j)fluoranthene (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: Benzo(a)fluoranthene (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: Benzo(e)pyrene (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: Benzo(a)pyrene (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: Perylene (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: Indeno(1,2,3-c,d)pyrene (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: Dibenzo(a,h)anthracene (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: Benzo(g,h,i)perylene (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer.
  • Parameter or Variable: Total PAHs (calculated); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/mass spectrometer; Sampling and Analyzing Method: Sum of individual PAHs.
  • Parameter or Variable: Aldrin (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: Dieldrin (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: Endrin (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: Endrin Aldehyde (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: Endrin Ketone (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: Heptachlor (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: Heptachlor-Epoxide (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: Oxychlordane (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: Alpha-Chlordane (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: Gamma-Chlordane (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: Trans-Nonachlor (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: Cis-Nonachlor (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: Alpha-HCH (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: Beta-HCH (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: Delta-HCH (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: Gamma-HCH (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: DDMU (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: 2,4'-DDD (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: 4,4'-DDD (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: 2,4'-DDE (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: 4,4'-DDE (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: 2,4'-DDT (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: 4,4'-DDT (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: 1,2,3,4-Tetrachlorobenzene (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: 1,2,4,5-Tetrachlorobenzene (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: Hexachlorobenzene (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: Pentachloroanisole (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: Pentachlorobenzene (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: Endosulfan II (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: Endosulfan I (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: Endosulfan Sulfate (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: Mirex (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: Chlorpyrifos (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 1 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 2 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 3 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 4/10 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 7/9 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 6 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 8/5 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 14 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 11 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 12 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 13 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 15 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 19 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 30 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 18 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 17 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 27 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 24 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 16/32 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 34 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 23 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 29 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 26 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 25 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 28/31 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 21/20/33 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 22 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 36 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 39 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 38 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 35 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 37 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 54 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 50 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 53 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 51 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 45 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 46/69/73 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 52 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 43 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 49 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 48/75/47 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 65 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 62 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 44 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 59 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 42 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 72 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 71 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 68/41/64 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 40/57 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 67 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 58 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 63 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 61/74 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 76/70 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 66/80 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 55 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 56 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 60 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 79 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 78 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 81 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 77 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 104 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 96/103 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 100 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 94 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 102/98 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 121/93/95 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 88 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 91 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 92 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 84/90 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 101/89/113 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 99 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 119 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 112 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 120/83 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 97/125/86 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 116/117 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 111/115/87 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 109 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 85 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 110 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 82 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 124 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 108/107 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 123 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 118/106 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 114/122 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 105/127 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 126 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 155 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 150 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 152 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 148/145 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 136/154 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 151 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 135 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 144 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 147 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 149/139 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 140 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 143 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 134/133 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 165/131 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 142/146/161 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 153/168 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 132 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 141 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 137 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 130 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 164/163 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 138/160/158 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 129 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 166 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 159 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 162 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 128/167 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 156 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 157 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 169 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 188 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 184 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 179 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 176 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 186/178 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 175 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 187/182 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 183 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 185 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 174 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 181 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 177 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 171 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 173 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 192/172 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 180/193 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 191 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 170/190 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 189 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 202 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 201 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 204 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 197 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 200 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 198 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 199 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 203/196 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 195 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 194 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 205 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 208 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 207 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 206 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: PCB 209 (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection.
  • Parameter or Variable: Total HCH (calculated); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection; Sampling and Analyzing Method: Sum of HCHs.
  • Parameter or Variable: Total Chlordane (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection; Sampling and Analyzing Method: Sum of Chlordanes.
  • Parameter or Variable: Total DDT (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection; Sampling and Analyzing Method: Sum of DDTs.
  • Parameter or Variable: Total PCB (measured); Units: ng/ea; Observation Category: laboratory analysis; Sampling Instrument: gas chromatograph/electron capture detection; Sampling and Analyzing Method: Sum of PCBs.
Acquisition Information (collection)
Instrument
  • chromatograph
Last Modified: 2024-04-10T23:32:25Z
For questions about the information on this page, please email: ncei.info@noaa.gov